Dental Handheld Portable Wireless X-ray Unit

X2

Ships from/sold by Dentaluck.com

481 items in stock 519 items sold!

Unit(s)

Loyalty program By buying this product you can collect up to 8 loyalty points. Your cart will total 8 points that can be converted into a voucher of $8.00.


Shipping Costs: remove
Wholesale

Introduction

This portable wireless X-ray unit is very convenient for dentists visiting their patient out of the clinics. This unit is specially designed to produce high-quality dental x-ray images. The tube head is equipped with excellent radiation-shield protection (except the radial mouth,and tests have shown that the radial index is zero. Safety is guaranteed. While using a small amount of radiation there is no need for protection.There are films included for testing purpose and all the consumables can be replaced by other similar products. Effectively diagnose your patients and follow-up on prior treatments with our brand-new, low-radiation X-Ray machine. Non-film inspection and storage can be realized when corresponding to a sensor.

All the components of this product were originally imported to achieve an acceptable tolerance required for the digital controls and the machine. By doing this, product performance is more stable and reliable. This machine uses components from well established suppliers, allowing us to deliver to our customers a product of high quality.

Mainly Use

The machine is mainly used in dental clinics,to check out before treatment,and to be used for comparison and confirmation during and after treatment. It is an indispensable piece of equipment for daily work within a clinic. Some examples of its use include checking tissue structure,the depth of the root,the degree of inflammation,and for the inner inspection of broken teeth.

What is "Green" X-ray Machine

This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).The tube voltage frequency of this machine is 30 KHz,and the tube current is 0.1 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."

Technical Parameters

  • 110v±10% and 220V±10% (We stock the item specail for the customer all over the world)

  • Power: 24V 8000MA Charger: 220V/110V, 50Hz

  • Tube current: 0.1mA

  • Rating: 60W

  • Frequency: 30 KHz

  • Exposure time: 1-9 seconds optional

  • Leak radiation: <20µgy/h(12lb)

  • Focus Skin Distance: >20cm

  • Tube voltage: 70KV

  • Relative Humidity(RH) < 80%

  • Storage conditions: 5-40 degrees Celsius, relative Humidity

  • Net weight: 2.5 kg

Feature

  • "Green" X-ray machine.Low amount of radiation, safeguards patients and staff from overdoes of radiation exposure.

  • Delivers fast response speeds and higly-accuracy output indexes

  • Wireless, can be charged.

  • Uses Toshiba 0.3 micro-focus tube, ensuring crystal-clear images.

  • The excellent radiation-shield protection for tube head

  • High-frequency design makes unit portable and compact, saving you space, easy to carry.

  • FDA Compliant, CE Certification, ISO9001 Quality Certification

How to use

Please see the User Manual (Click Here to download it)to see how to set up and use this machine

Operation of the Main Unit

  • Upon receiving,open the box and check the product for possible damage during shipping.
  • Make sure the fittings on the encasement list are packaged within the box.
  • Install the blue ray tube to the foreside of the ball head,then tighten it.
  • Turn on the Power;the pilot lamp will be light up.During this time,the digital tube will show the fore setting time. Now the equipment is in standby mode.
  • Setting the time (Skip to next step if unneeded) Use the "SET","+",and" -" buttons to reset the time as follows: press SET,the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
  • Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
  • Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.
  • After positioning,use the ON/OFF on the main Unit, to take pictures. (Notice: gently press 0.5 sec to turn it on)
  • After exposure to the tube,press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray,so the dental films can be used again).
  • Repeat step 6 to reset the picturing time.To repeat the picturing process,please repeat steps 7 to 9.
  • Turn the power off when the work is finished,press POWER, making sure the pilot lamp is off.Don't keep the machine long in standby mode.

Developina the Dental film

  • Picture the tooth following the right operating procedure of the X-ray Unit,then take the film out from the mouth.
  • Use a syringe to extract 4-5 mi of imaging liquid.
  • Transfuse the liquid into the bag,nip both the ends and the sides of the bag with thumbs and first fingers(knead the film).
  • Open the end of the bag about ten minutes after transfusing the liquid into the bag.
  • Take the film out,put it into clear water,and rinse it. Don't wipe the surface of the film with the surface to prevent damage to the image.
  • Observe and diagnose after the film becomes dry.

Points for Attention

  • Make sure the angle of film,tooth,and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
  • Remember to turn the power 0ffwhen work is done.
  • Charge the battery if the machine cannot work and the red lamp lignt
  • After turning the power on,wait one minute before taking pictures,this allows the ray to provide a steady output.
  • The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of filming.
  • When taking pictures,the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
  • Use high quality tooth film and developing liquid to make clear pictures.
  • Handle the ball head gently while in use,so as not to damage the delicate component.
  • We usually set the time between 3-8 seconds when taking pictures,but the actual time of ray output is 0.2-0.5 seconds.
  • If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
  • Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
  • Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
  • Other requests accordance with the scope of the technical parameters.
  • Please read the manual carefully before using.

Warranty
We offer a 1 year warranty as follows.
(Note: When warranty expires,we charge for the replacement and repairs of the machine and components.)
The following cases are not within the scope of this warranty:

  • Intentional damages to the machine which cannot be repaired.
  • Opening the machine for purposes of reverse engineering for means of imitation.
  • Getting burned using the wrong power supply.
  • Modifications to the machine,such as the addition of extra components to the machine resulting in damage that prevents the normal use


The Angle should be proper while taking a picture. The film should be put vertically behind the tooth to be taken a picture while the case is for the front teeth; and the film should be put transversely behind the tooth to be taken a picture while the case is for the back teeth. The patient should use forefinger to press the film behind the tooth gently.
*Kodak film as the sent samples are strongly recommended.
Reference of the Angles

 

 

 

Tooth

Upper

Lower

1-2

42

-15

3

45

-18

4-5

30

-10

6-8

28

-5

Reference of the time of exposure


Tooth

Adult

Child

Central & Lateral

2.5-3.25

2-2.7

Cuspid & 1st Bicuspid

3.2-4

2.7-3.5

Upper 5,6

3.5-4

3-3.5

Upper 7,8

7.5-8

7-7.5

Lower 5,6

4-4.5

3.5-4

Lower 7,8

4-4.5

3.5-4

Trouble Shooting Instructions

Failure

Reason

Solution

The pilot lamp lights up but the digital tube unit does net show the fore setting time

Abnormal Power supply

Charge the batterg

Circuit damaged

Send the product back to the factory or distributor to repair

No image is taken while the counting down works

Circuit damaged or connection problem

Send the product back to the factory or distributor to repair

The time setting does not work

Error in the control program

Re-start on the machine

Problem with the SET button

Send it for a repair

No counting down after press Start

The pilot lamp light is on for the SET

Shut down the SET mode

Blurred film

The film,tooth,and ball head
are not stable while taking a picture

Operate again rightly

The film is too far from the tooth that is taken a picture

Operate again rightly

Wrong angle of taking a picture

Operate again rightly

The image is too light

The time of exposure is too short

Reset the exposure time and make it longer

The time of developing the film is too short

Lengthen the developing time

The image is too dark

The time of exposure is too long

Reset theexposure time and make it shorter

The time of developing the film is too long

Shorten the developing time

Other possible reasons for a
Blurred film or a blank film

The film is of poor quality

Change for a better film

The imaging liquid is of poor quality

Change for a better liquid

The temperature is too low while developing the film

Develop the film In a higher temperature

 

 

Units and Pictures (what you see what you get)

  • 1 X Main Unit
  • 1 x Dental Film Position Indicator
  • 1 x Charger
  • 5 x Dental Films for Commissioning
  • 1 x Packing Instruction
  • 1 x Warranty Card
  • 1 x Large Packing Box
  • 2 x Key of the packing box

 

No customer comments for the moment.

Add a comment

After-sales service
Product practical
Gave a faithful account
MostDental

Top Sellers